Product Material
Home >>> Product Class >>> Pepperl Fuchs >>> isolated barriers
易展国际 >>> 展馆展区 >>> Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB
[

Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB

]
sendmsg
Product Name: Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB
Product Model: KFD2-SR2-EX.1.W.LB
Manufacturer: Pepperl Fuchs
file:No Related Documents


Product Description

Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB

Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB

Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB



Switch Amplifier KFD2-SR2-Ex1.W.LB

Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB

Features
• 1-channel isolated barrier
• 24 V DC supply (Power Rail)
• Dry contact or NAMUR inputs
• Usable as signal splitter (1 input and 2 outputs)
• Relay contact output
• Fault relay contact output
• Line fault detection (LFD)
• Reversible mode of operation
• Up to SIL 2 acc. to IEC 61508/IEC 61511

Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB

Function
This isolated barrier KFD2-SR2-Ex1.W.LB is used for intrinsic safety applications. It transfers digital signals (NAMUR sensors/mechanical
contacts) from a hazardous area to a safe area. The proximity sensor or switch controls a form C changeover relay contact for the safe area load. The normal output state can be reversed using switch S1. Switch S2 allows output II to be switched between a signal output or an error message
output. Switch S3 is used to enable or disable line fault detection of the field circuit. During an error condition, the relays revert to their deenergized
state and the LEDs indicate the fault according to NAMUR NE44. A unique collective error messaging feature is available when used with the Power Rail system.Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB


General specifications
Signal type Digital Input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply
Connection Power Rail or terminals 14+, 15-
Rated voltage Ur 20 ... 30 V DC
Ripple ≤ 10 %
Rated current Ir ≤ 50 mA
Power dissipation 1 W
Power consumption < 1.3 W
Input
Connection side field side
Connection terminals 1+, 2+, 3-
Rated values acc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA
Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detection breakage I ≤ 0.1 mA , short-circuit I > 6 mA
Pulse/Pause ratio ≥ 20 ms / ≥ 20 ms
Output
Connection side control side
Connection output I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Output I signal ; relay
Output II signal or error message ; relay
Contact loading 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
Minimum switch current 2 mA / 24 V DC
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Mechanical life 107 switching cycles

Pepperl+Fuchs isolated barrier KFD2-SR2-EX.1.W.LB


Detailed models;

P+F KCD2-SCD-1
P+F KCD2-SCD-EX1
P+F KCD2-SR-EX1.LB
P+F KCD2-SR-EX2
P+F KCD2-STC-1
P+F KCD2-STC-EX1
P+F KCD2-STC-EX1.2O
P+F KCD2-UT2-EX1
P+F KFA6-SR2-Ex1.W
P+F KFD0-SD2-Ex1.1045
P+F KFD2-CD2-EX1
P+F KFD2-CRG2-EX1.D
P+F KFD2-DWB-1.D
P+F KFD2-EB2
P+F KFD2-GU-1
P+F KFD2-GUT-Ex1.D
P+F KFD2-SCD2-EX2.LK
P+F KFD2-SH-EX1.T.OP
P+F KFD2-SOT2-Ex2
P+F KFD2-SR2-Ex1.W.LB
P+F KFD2-SR2-Ex2.W
P+F KFD2-ST2-Ex2
P+F KFD2-STC4-1
P+F KFD2-STC4-EX2 
P+F KFD2-STC4-Ex2
P+F KFD2-UT2-1
P+F KFD2-UT2-2
P+F KFD2-UT2-EX1
P+F KFD2-UT2-Ex2
P+F KFD2-VR4-EX1.26

Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报


Product Search
Contact Us
Browse by Category
Copyright@ 2003-2025   HONGKONG XIEYUAN TECH CO.,LIMITED