Product Material
Home >>> Product Class >>> Pepperl Fuchs >>> isolated barriers
易展国际 >>> 展馆展区 >>> Pepperl+Fuchs HiC2031ES Enhanced Safety SMART Current Driver
[

Pepperl+Fuchs HiC2031ES Enhanced Safety SMART Current Driver

]
sendmsg
Product Name: Pepperl+Fuchs HiC2031ES Enhanced Safety SMART Current Driver
Product Model: HiC2031ES
Manufacturer: Pepperl Fuchs
file:No Related Documents


Product Description

Primary: Pepperl+Fuchs HiC2031ES, enhanced safety current driver, SMART loop driver, HART current source Technical: ATEX IECEx current driver, Foundation Fieldbus driver, 4-20mA loop power, intrinsic safety interface Application: Hazardous area current driver, oil & gas transmitter power, process control loop driver Features: Enhanced safety design, dual protocol support, LED diagnostics,

Pepperl+Fuchs HiC2031ES Enhanced Safety SMART Current Driver

Pepperl+Fuchs HiC2031ES Enhanced Safety SMART Current Driver



The Pepperl+Fuchs HiC2031ES is a high-performance, enhanced safety active current driver engineered for the most demanding intrinsically safe (IS) applications. As part of Pepperl+Fuchs' enhanced safety series, this device provides reliable drive current for SMART field transmitters while enabling digital HART and Foundation Fieldbus communication in critical hazardous area control loops.


Key Features 

  • Enhanced Safety Design: Certified for demanding hazardous area classifications with ATEX and IECEx approvals, typically for Zone 1/21, Gas Group IIC, and Temperature Class T4 applications, providing maximum safety assurance.

  • Active 4-20mA Loop Driver: Functions as an active current source within the control loop, supplying precise 4-20mA current to field transmitters while carrying analog process signals with exceptional stability.

  • Dual Protocol Support: Specifically optimized for HART (Highway Addressable Remote Transducer) and Foundation Fieldbus (FF) H1 communication protocols, enabling advanced digital configuration, diagnostics, and data exchange with field devices.

  • Superior Signal Integrity: Features advanced circuitry that minimizes noise and ensures high signal accuracy, critical for maintaining precise process control and reliable digital communication in electrically noisy industrial environments.

  • Comprehensive Diagnostics: Equipped with multi-status LED indicators providing real-time visual feedback on power, communication activity, loop status, and fault conditions for immediate troubleshooting.

  • Robust Industrial Construction: Compact DIN rail mounting design with secure screw terminal connections, built to withstand vibration, temperature variations, and harsh industrial conditions.


Parameter Specification
Manufacturer Pepperl+Fuchs
Model Number HiC2031ES
Product Series Enhanced Safety (ES) Series
Function Active SMART Current Driver / Loop Interface
Supported Protocols HART, Foundation Fieldbus H1
Output Current Range 4-20 mA (driving capability)
Loop Voltage Compliance Sufficient for field device and wiring requirements
Communication Support Digital signal superimposition on analog current
Safety Certifications ATEX, IECEx (Zone 1/21, IIC, T4 typical)
Mounting DIN Rail 35mm
Connection Type Screw terminals
Operating Temperature -20°C to +60°C (standard range)
Width Approximately 12.5mm (single module)

Applications

  • Critical Process Industries: Powering and communicating with SMART transmitters in oil refineries, petrochemical plants, and gas processing facilities with explosive atmospheres.

  • Pharmaceutical & Fine Chemical: Interface for precise measurement and control loops in potentially hazardous production environments.

  • Power Generation: Monitoring and control loops in coal, biomass, and gas-fired plants with explosive dust or gas risks.

  • Offshore Platforms: Reliable current driving for field instrumentation in demanding marine and offshore environments.

  • Safety Instrumented Systems (SIS): Providing loop power and communication for safety-critical transmitters in SIL-rated applications.

Why Choose Pepperl+Fuchs HiC2031ES?

Pepperl+Fuchs HiC2031ES | SMART Current Driver | Intrinsic Safety | HART/FF | Enhanced Safety

  • Maximum Hazardous Area Compliance: Meets the highest international standards for intrinsic safety in explosive atmospheres.

  • Uncompromised Signal Quality: Advanced design ensures minimal signal distortion for both analog control and digital communication.

  • Advanced Diagnostics: Comprehensive status indication enables predictive maintenance and reduces system downtime.

  • Pepperl+Fuchs Reliability: Backed by decades of expertise in manufacturing industrial interface and safety equipment.

  • Space-Efficient Solution: Compact design allows high-density installation in control panels while providing full functionality.

    Pepperl+Fuchs HiC2031ES enhanced safety SMART current driver. 4-20mA loop power, HART/Foundation Fieldbus, ATEX/IECEx, DIN rail mount for hazardous areas.

Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报


Product Search
Contact Us
Browse by Category
Copyright@ 2003-2026   HONGKONG XIEYUAN TECH CO.,LIMITED