HONGKONG XIEYUAN TECH CO.,LIMITED
Main camp product:
MTL safety barrier
Pepperl + fuchs safety barrier
ABB DCS
Siemens CPU
Siemens S7-1500
Siemens S7-200
Siemens S7-400
Siemens S7-300
Siemens ET200
Schneider PLC
Mitsubishi PLC
Omron PLC
Siemens PLC
SIEMENS HMI PANEL
Siemens S7-1200
Home
Intro
Product
News
Article
Download
Job
Contact
Product Search
Contact Us
Contact Person: Jessica Yu; Tel: 86-027-85508558 Fax: +86 027-85309780 Mobile: 86-15871691193 (Whatsapp & Telegram) Email: sales1@hkxytech.com; Jackie@hkxytech.com Skype: Jackie@hkxytech.com
Browse by Category
Siemens
Yokogawa
Phoenix
Hirschman
Honeywell
ABB
MTL
Pepperl Fuchs
Schneider
Emerson
Weidmuller
Moxa
Endress+Hauser
Allen Bradley
Mitsubishi
IFM
Hach
Norgren
Fluke
Danfoss
Product List
Home
>>>
Product Class
>>>
Pepperl Fuchs
More Categories
Relay Module
Current Driver
Terminal and Junction Boxes
Sensor
isolated barriers
Switch Amplifier
Product Image
Product Name/Model
Product Description
Pepperl+Fuchs K-LB-1.30G 1-Channel Surge Protection Barrier
K-LB-1.30G
The device limits induced transients of different causes, e. g. lightning or switching operations. The limitation is achieved by diverting the current to earth and limiting the signal loop voltage during the duration of the overvoltage pulse.
Pepperl+Fuchs KFD2-SR2-EX2.W 2-channel Switch Amplifier
KFD2-SR2-EX2.W
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor
Pepperl+Fuchs K-LB-2.30G 2-channel Surge Protection Barrier
K-LB-2.30G
2-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 30 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 4, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V
Pepperl+Fuchs KFD2-STC5-1 1-channel Transmitter Power Supply
KFD2-STC5-1
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Rated voltage: 18 ..
Pepperl+Fuchs KCD2-RR2-EX1 1-channel Resistance Repeater
KCD2-RR2-EX1
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ...
Pepperl+Fuchs KCD2-STC-1 1-channel SMART Transmitter Power Supply
KCD2-STC-1
1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): S
Pepperl+Fuchs KCD2-SCD-1 1-channel SMART Current Driver
KCD2-SCD-1
1-channel signal conditioner, 24 V DC supply (Power Rail), Current output up to 900 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Housing width 12.5 mm, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC
Pepperl+Fuchs KCD2-STC-EX1 1-channel SMART Transmitter Power Supply
KCD2-STC-EX1
1-channel isolated barrier 24 V DC supply (Power Rail) Input for 2-wire SMART transmitters and current sources Output for 4 mA ... 20 mA or 1 V ... 5 V Housing width 12.5 mm Up to SIL 2 (SC 3) acc. to IEC/EN 61508
Pepperl+Fuchs KCD2-SR-Ex1.LB 1-channel Switch Amplifier
KCD2-SR-Ex1.LB
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm
Pepperl+Fuchs K-LB-2.6G 2-channel Surge Protection Barrier
K-LB-2.6G
2-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 6 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset)
Pepperl+Fuchs K-LB-1.30 1-channel Surge Protection Barrier
K-LB-1.30
1-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 30 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset)
Pepperl+Fuchs KFD2-CD-EX1.32 1-channel Current/Voltage Driver
KFD2-CD-EX1.32
1-channel isolated barrier, 24 V DC supply (Power Rail), Current and voltage input, Current or voltage output, Factory configured input/output, Accuracy 0.1 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Signal: 1 x 0 ... 20 mA
Pepperl+Fuchs KCD2-SR-Ex2 2-channel Switch Amplifier
KCD2-SR-Ex2
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2
Pepperl+Fuchs KFD2-UT2-EX1 1-channel Universal Temperature Converter
KFD2-UT2-EX1
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2
Pepperl+Fuchs KFD2-SCD2-EX1.LK 1-channel SMART Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Test sockets
Pepperl fuchs KFA5-SR2-Ex2.W.IR isolated barriers
KFA5-SR2-Ex2.W.IR
Pepperl fuchs KFA5-SR2-Ex2.W.IR isolated barriers Pepperl fuchs KFA5-SR2-Ex2.W.IR isolated barriers Pepperl fuchs KFA5-SR2-Ex2.W.IR isolated barriers
Pepperl fuchs KFA5-SR2-Ex2.W isolated barriers
KFA5-SR2-Ex2.W
Pepperl fuchs KFA5-SR2-Ex2.W isolated barriers Pepperl fuchs KFA5-SR2-Ex2.W isolated barriers Pepperl fuchs KFA5-SR2-Ex2.W isolated barriers
Pepperl+Fuchs isolated barrier KFD2-SCD2-EX1.LK
KFD2-SCD2-EX1.LK
Pepperl+Fuchs isolated barrier KFD2-SCD2-EX1.LK Pepperl+Fuchs isolated barrier KFD2-SCD2-EX1.LK Pepperl+Fuchs isolated barrier KFD2-SCD2-EX1.LK
Pepperl+Fuchs Frequency Converter with Trip Values KFU8-UFC-Ex1.D
KFU8-UFC-Ex1.D
Pepperl+Fuchs Frequency Converter with Trip Values KFU8-UFC-Ex1.D Pepperl+Fuchs Frequency Converter with Trip Values KFU8-UFC-Ex1.D Pepperl+Fuchs Frequency Converter with Trip Values KFU8-UFC-Ex1.D
Pepperl+Fuchs Isolated Barrier KFD2-STC4-EX2
Pepperl+Fuchs Isolated Barrier KFD2-STC4-EX2 Pepperl+Fuchs Isolated Barrier KFD2-STC4-EX2 Pepperl+Fuchs Isolated Barrier KFD2-STC4-EX2
上一Pages
1
2
3
4
5
6
...
16
下一Pages
上一Pages
下一Pages
Copyright@ 2003-2025
HONGKONG XIEYUAN TECH CO.,LIMITED