Product overview
MTL5514 1channel DI relay output + LFD alarm product in stock
MTL5514 1channel DI relay output + LFD alarm product in stock
MTL5514 product specification as below for your reference.
MTL5514 1channel DI relay output + LFD alarm product in stock
MTL4514/B – MTL5514 SWITCH/ PROXIMITY DETECTOR
INTERFACE 1-channel, line fault detection, phase reversal
The MTLx514 enables a safe–area load to be controlled, through a
relay, by a proximity detector or switch located in a hazardous area. Line
faults are signalled through a separate relay and indicated on the top of the
module. Switches are provided to select phase reversal and to enable the line
fault detection.
SPECIFICATION
MTL5514 1channel DI relay output + LFD alarm product in stock
Number of channels :One
Location of switch
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous
location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous
area, if suitably certified
Div.1, Group A, hazardous
location
Hazardous–area inputs
Inputs conforming to BS
EN60947–5–6:2001 standards for proximity detectors (NAMUR)
Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
Input/output characteristics
Normal phase
Outputs closed if input >
2.1mA (< 2kΩ in input circuit)
Outputs open if input <
1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω)
nominal
Line fault detection (LFD) (when selected)
User-selectable via switches
on the side of the unit. Line faults are indicated by an LED. Line fault relay
is energised and channel output relay de-energised if input line-fault detected
Open-circuit alarm on if Iin
< 50µA
Open-circuit alarm off if Iin >
250µA
Short-circuit alarm on if Rin
< 100Ω
Short-circuit alarm off if Rin
> 360Ω
Note: Resistors must be fitted
when using the LFD facility with a contact input
500Ω to 1kΩ in series with
switch 20kΩ to 25kΩ in parallel with switch
Safe-area output
MTL4514 & MTL5514
Channel: Single pole relay
with changeover contacts
LFD: Single pole relay with
changeover contacts
MTL4514B
Channel: Single pole relay
LFD: Single pole relay
LED indicators
Green: power indication
Yellow: channel status, on
when output energised
Red: LFD indication, on when
line fault detected
Maximum current consumption
25mA at 24V dc
Power dissipation within unit
0.6W at 24V
Safety description
Uo=10.5V Io=14mA Po=37mW Um =
253V rms or dc
Other related models for MTL5500 range as below for your reference.
MTL5514 1channel DI relay output + LFD alarm product in stock
MTL5018AC
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513
MTL5514
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5522
MTL5523
MTL5523V – V
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS
MTL5541S
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5991
MTL5531
MTL5532
MTL5533
MTL5561
MPA5500
MTL5051
MTL5053
MTL5314
MTL5599
MTL5514 1channel DI relay output + LFD alarm product in stock
If you have any other question about MTL5514, please feel free to contact me here!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-
Mobile :86-(Whatapp&Wechat
is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报