Product overview
MTL5516C 2 channel DI with changeover relay output isolated barrier
MTL5516C 2 channel DI with changeover relay output isolated barrier
MTL5516C product specification as below for your reference.
MTL5516C 2 channel DI with changeover relay output isolated barrier
MTL4516/C – MTL5516C SWITCH/
PROXIMITY DETECTOR INTERFACE 2-channel, with line fault detection
The MTLx516/C enable two
safe-area loads to be controlled by a switch or proximity detector located in a
hazardous-area. When selected, open or short circuit conditions in the field
wiring are detected by the linefault-detect (LFD) facility and also indicated
on the top of the module. Phase reversal for each channel is selected by a
switch on the side of the module and output is provided by changeover relay
contacts.
SPECIFICATION
MTL5516C 2 channel DI with changeover relay output isolated barrier
Number of channels :Two
Location
of switches
Zone 0,
IIC, T6 hazardous area
Div. 1,
Group A hazardous
location
Location of proximity detector
Zone 0,
IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous
location Hazardous-area inputs
Inputs
conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)
Voltage
applied to sensor
7 to 9V
dc from 1kΩ ±10%
Input/output
characteristics
Normal
phase
Outputs
closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs
open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis:
200µA (650Ω) nominal
Line
fault detection (LFD) (when selected)
User-selectable
via switches on the side of the unit. Line faults are indicated by an LED for
each channel. The channel output relay is de-energised if an input line fault
is detected.
Open-circuit
alarm on if Iin < 50µA
Open-circuit
alarm off if Iin > 250µA
Short-circuit
alarm on if Rin < 100Ω Short-circuit alarm off if Rin > 360Ω
Note:
Resistors must be fitted when using the LFD facility with a contact input 500Ω
to 1kΩ in series with switch 20kΩ to 25kΩ in parallel with switch
Safe-area
output
Two
single-pole relays with changeover contacts Note: reactive loads must be
adequately suppressed
Maximum
current consumption :35mA at 24V
Power
dissipation within unit: 0.84W at 24V
LED
indicators
Green:
power indication Yellow: two: channel status, on when output energised Red:
two: LFD indication, on when line fault detected
Safety
description (each channel)
Uo=10.5V
Io=14mA Po=37mW Um = 253V rms or dc
Other related models for MTL5516C as below
MTL5516C 2 channel DI with changeover relay output isolated barrier
MTL5018AC
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513
MTL5514
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5522
MTL5523
MTL5523V – V
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS
MTL5541S
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5991
MTL5531
MTL5532
MTL5533
MTL5561
MPA5500
MTL5051
MTL5053
MTL5314
MTL5599
MTL5516C 2 channel DI with changeover relay output isolated barrier
If you have any other question about mtl5516C, please feel free to contact me here!
Contact detail
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-
Mobile :86-(Whatapp&Wechat
is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com
Leave a message for product
- 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
- 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报