Zhejiang FUXIA Medical Technology Co.,Ltd.
Main camp product:
Laminar flow cabinet
air sampler
pass box and weighing booth
Air shower
Class 100 clean cabinet
Class II biological safety cabinet
Fume hood
Clean sampling vehicle
Home
Intro
Product
News
Article
Download
Job
Contact
Product Search
Contact Us
Contact person:July Mobile phone:+86-18158752208 Zip code:312300 Address:Beside 104 National Road, Daoxu Street, Shangyu District, Shaoxing City, Zhejiang Province Email:zjsjsales002@hotmail.com QQ:3366561937 Wechat:zjsjsales002 Whats app:+86-18158752208 Skype:julyzjsj
Browse by Category
Laminar flow cabinet
Biological safety cabinet
Fume hood
Pass box
air shower
Autoclave/Steam sterilizer
Incubator
Drying Oven
Clean sampling vehicle
Medical hand washing sink
Weighing booth
Particle counter
Air sampler
Muffle furnace
water distiller
ozone generator
water bath
Air purifier
vacuum pump
Colony counter
Article
Tips for extending the life of a 100-stage purification table
The 100-stage purification table shall be composed of box body, fan, hepa filter, operation switch and other components. The work table is made of stainless steel, the box is made of color steel plate, and the purification unit is made of a fan system with adjustable air volume. By adjusting the working state of the fan, the average wind speed in the clean work area can be kept within the rated range, and the service life of the high efficiency filter is effectively extended. Next, let's look at some tips for extending the life of the 100-stage purification table:
1. According to the actual use, remove the primary filter and clean it regularly. The cleaning cycle is generally 3-6 months. (if not cleaned for a long time, dust will affect the insufficient air intake and reduce the cleaning effect.)
2. Generally, when the working voltage of the fan is adjusted to a relatively high point and still cannot reach the ideal wind speed, it means that there is too much dust in the hepa filter (the filter hole on the filter material has been basically blocked, it should be updated in time). The service life of the general hepa filter is 18 months.
3, according to the environmental cleaning procedures, regularly remove the filter material in the coarse filter filter cleaning, the interval time is generally 3 to 6 months.
4. When the voltage of the wind unit is adjusted to large zui, the wind speed in the work area still cannot reach 0.3m/s, that is to say, the air hepa filter must be replaced.
5. When replacing hepa filter, please pay attention to whether the model, specification and size are correct (the original configuration of the manufacturer), follow the arrowhead wind direction device, and pay attention to the sealing around the filter, no leakage occurs.
6, when the normal replacement or cleaning of the initial effect of the filter air filter, still can not reach the ideal section of the wind speed, the fan should be adjusted to work voltage, so as to achieve the ideal uniform wind speed.
7. When replacing the hepa filter, apply the dust particle counter to check whether the four peripheral seals are in good condition. Adjust the wind unit voltage to keep the average wind speed in the working area within the range of 0.4±10%m/s. Check the purification efficiency with the dust particle counter.