Zhejiang FUXIA Medical Technology Co.,Ltd.
Main camp product:
Laminar flow cabinet
air sampler
pass box and weighing booth
Air shower
Class 100 clean cabinet
Class II biological safety cabinet
Fume hood
Clean sampling vehicle
Home
Intro
Product
News
Article
Download
Job
Contact
Product Search
Contact Us
Contact person:July Mobile phone:+86-18158752208 Zip code:312300 Address:Beside 104 National Road, Daoxu Street, Shangyu District, Shaoxing City, Zhejiang Province Email:zjsjsales002@hotmail.com QQ:3366561937 Wechat:zjsjsales002 Whats app:+86-18158752208 Skype:julyzjsj
Browse by Category
Laminar flow cabinet
Biological safety cabinet
Fume hood
Pass box
air shower
Autoclave/Steam sterilizer
Incubator
Drying Oven
Clean sampling vehicle
Medical hand washing sink
Weighing booth
Particle counter
Air sampler
Muffle furnace
water distiller
ozone generator
water bath
Air purifier
vacuum pump
Colony counter
News
Can the air filter of the biosafety cabinet be reused? How to clean?
Most biosafety cabinet air filters are not recommended for repeated cleaning and use, because the microporous structure of the filter may be damaged by cleaning, thus affecting the filtration effect. Filters need to be replaced regularly to ensure the effectiveness of the biosafety cabinet.
For some HEPA filters, the manufacturer may provide cleaning and regeneration services. Before cleaning, it is necessary to remove the filter and clean the surface, and use appropriate cleaning agents and tools during cleaning to avoid mechanical damage to the filter. After cleaning, the filter needs to be dried and regenerated to restore the filtering effect of the filter.
It should be noted that for some filters that may contain harmful microorganisms and biohazard substances, the cleaning process may produce hazardous waste and pollution, which requires special treatment and compliance with relevant laws, regulations and code requirements. It is recommended to read the instructions and operation guidelines provided by the manufacturer carefully before cleaning, or consult professional technicians.
To replace the filter of the biosafety cabinet, follow the following steps:
Confirm the biosafety cabinet model and filter specifications, and select the HEPA filter that meets the requirements.
Close the biosafety cabinet and unplug it.
Open the front panel of the biosafety cabinet and remove dust and dirt from around the old filter.
Remove the old filter and dispose of it according to the filter replacement instructions.
Wipe the inside of the filter tank with a clean damp cloth or cotton swab to remove dust and dirt.
Remove the new filter and place it in the filter tank in its specified direction. Make sure the filter is firm and not loose.
Close the front panel of the biosafety cabinet, plug it in, and open the biosafety cabinet.
Perform filter tests to check that the air flow is normal and there is no air leakage.
Previous:
Does the use of biosafety cabinets require training and assessment? How to conduct training and asse
Next:
Safety tips when using laboratory fume hoods