Zhejiang FUXIA Medical Technology Co.,Ltd.
Main camp product:
Laminar flow cabinet
air sampler
pass box and weighing booth
Air shower
Class 100 clean cabinet
Class II biological safety cabinet
Fume hood
Clean sampling vehicle
Home
Intro
Product
News
Article
Download
Job
Contact
Product Search
Contact Us
Contact person:July Mobile phone:+86-18158752208 Zip code:312300 Address:Beside 104 National Road, Daoxu Street, Shangyu District, Shaoxing City, Zhejiang Province Email:zjsjsales002@hotmail.com QQ:3366561937 Wechat:zjsjsales002 Whats app:+86-18158752208 Skype:julyzjsj
Browse by Category
Laminar flow cabinet
Biological safety cabinet
Fume hood
Pass box
air shower
Autoclave/Steam sterilizer
Incubator
Drying Oven
Clean sampling vehicle
Medical hand washing sink
Weighing booth
Particle counter
Air sampler
Muffle furnace
water distiller
ozone generator
water bath
Air purifier
vacuum pump
Colony counter
News
Does the installation of the biosafety cabinet need to be connected to the exhaust duct
Biosafety cabinets generally need to be connected to discharge pipelines in order to discharge filtered exhaust gas into the outdoor or ventilation system. The discharge pipeline generally requires materials that are corrosion-resistant, have good sealing performance, and meet the requirements of local environmental regulations. During the installation process, it is necessary to pay attention to the installation position and angle of the discharge pipeline to avoid the backflow and accumulation of waste gas. If the discharge pipeline cannot be connected, it is necessary to use internal circulation to filter the exhaust gas and regularly replace the filter.
The installation of the discharge pipeline of the biosafety cabinet should be carried out by professional installation personnel, and the following steps need to be followed:
Determine the direction and location of the discharge pipeline to ensure smooth exhaust emissions after installation, while not affecting the use of other equipment and channels.
It is generally recommended to locate the discharge outlet outside the roof or wall to reduce the impact on the indoor environment and personnel.
Install discharge pipelines, usually using PVC or stainless steel materials, and choose the diameter and length of the pipeline according to the actual situation.
Install the exhaust outlet to ensure that it is tightly connected to the pipeline without air leakage. At the same time, it is necessary to install an exhaust fan to ensure that the exhaust gas can be discharged in a timely manner.
During the installation of discharge pipelines, attention should be paid to safety issues such as waterproofing and fire prevention, and relevant safety regulations and rules should be followed to ensure the safety and reliability of the installation process.
It should be noted that the discharge pipeline of the biosafety cabinet should be separated from the discharge pipeline of the ventilation system to avoid the risk of cross contamination and cross infection.