Product Description

Primary: Endress+Hauser FMU90-R11CA131AA3A, Prosonic FMU90, ultrasonic level transmitter, ultrasonic flow meter Technical: 4-20mA HART ultrasonic, non-contact level measurement, pump control transmitter, FDU9x sensor interface Application: Wastewater level monitoring, open channel flow, silo level measurement, alternating pump control Features: IP66 housing, 3 relay outputs, envelope curv

Endress+Hauser Prosonic FMU90-R11CA131AA3A Ultrasonic Level Transmitter

Endress+Hauser Prosonic FMU90-R11CA131AA3A
Ultrasonic Level Transmitter


Endress+Hauser Prosonic FMU90-R11CA131AA3A | Ultrasonic Level & Flow Transmitter

The Endress+Hauser FMU90-R11CA131AA3A is a versatile ultrasonic transmitter from the Prosonic S series, designed for continuous, non-contact level measurement of liquids, sludge, and bulk solids, as well as flow measurement in open channels and weirs . This field-mount version offers advanced pump control, limit detection, and flexible I/O options for demanding water/wastewater and industrial applications .

Key Features and Product Highlights

  • High Accuracy: ±2 mm + 0.17% of measured distance ensures precise level/flow control 

  • Flexible I/O: 1x 4-20mA HART output, 3x SPDT relays, and 1 sensor input for FDU9x series probes 

  • Integrated Pump Control: Supports alternating pump control, rake control, and limit detection 

  • Easy Commissioning: 6-line plain text display with 15 languages, menu-guided operation, and envelope curve display for on-site diagnostics 

  • Field Housing: IP66 / NEMA 4x enclosure for direct field installation; PC material 

  • Wide Power Range: 90-253 VAC supply for global compatibility 

  • Sensor Compatibility: Works with FDU9x series ultrasonic sensors; automatic sensor recognition 

  • Heartbeat Technology: Available for advanced diagnostics and verification (depending on configuration) 

Order Code Interpretation: FMU90-R11CA131AA3A

Position Code Interpretation
Approval R Non-hazardous area 
Application 1 Level + pump control, alternating 
Housing 1 Field housing, PC, IP66 NEMA 4x 
Operation C Backlit display + keypad 
Power Supply A 90-253 VAC 
Level Input 1 1x sensor FDU9x/8x 
Switch Output 3 3x relays, SPDT 
Output 1 1x 0/4-20mA HART 
Additional Input A None 
Data Logging A Basic version 
Language 3 English, Chinese, Japanese, Korean, Thai, Indonesian 
Additional Option A Basic version 

Technical Specifications

Parameter Specification
Manufacturer Endress+Hauser
Product Series Prosonic S FMU90
Measuring Principle Ultrasonic (time-of-flight) 
Measurement Range Up to 45 m (148 ft) with FDU9x sensors 
Accuracy ±2 mm + 0.17% of measured distance 
Resolution 1 mm 
Power Supply 90-253 VAC 
Outputs 1x 4-20mA HART, 3x SPDT relays 
Inputs 1x FDU9x/FDU8x ultrasonic sensor 
Housing Material PC (polycarbonate) 
Protection Rating IP66 / NEMA 4x 
Operating Temperature -40°C to +60°C (-40°F to +140°F) 
Display 6-line graphic backlit display 
Digital Communication HART 
Linearization Up to 32 points, pre-programmed for flumes/weirs 
Certifications CSA GP, ATEX (with compatible sensor) 


Applications

  • Level Measurement: Continuous, non-contact level of liquids, sludge, powders, and bulk solids in tanks, silos, and basins 

  • Flow Measurement: Open channel and weir flow monitoring in wastewater treatment plants and stormwater overflow basins 

  • Pump Control: Alternating pump control, rake control, and dry-run protection 

  • Limit Detection: High/low level alarms with relay outputs 

  • Environmental Monitoring: Water/wastewater treatment, stormwater management, and irrigation systems 

Endress+Hauser FMU90

  • All-in-One Solution: Combines level, flow, pump control, and limit functions in a single device, reducing hardware costs 

  • Proven Reliability: Over 30 years of ultrasonic measurement expertise from Endress+Hauser 

  • Simple Commissioning: Intuitive menu guidance with on-site envelope curve display speeds up installation and troubleshooting 

  • Global Support: Backed by Endress+Hauser's worldwide service network and extensive documentation 

  • Flexible Configuration: Multiple I/O options and compatibility with FDU9x sensors for application adaptability 

    Endress+Hauser Prosonic FMU90-R11CA131AA3A ultrasonic transmitter. ±2mm accuracy, 90-253VAC, 3 relays, 4-20mA HART, IP66, for level/flow/pump control.

Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报


Product Search
Contact Us
Browse by Category
Copyright@ 2003-2026   HONGKONG XIEYUAN TECH CO.,LIMITED