Honeywell Analytics XNX Universal Transmitter XNX-AMAV-NNIF1
XNX Aluminium
Transmitter ATEX/IEC with MPD Infrared Hydrocarbon (Propane) Sensor 0-100LEL
XNX-AMAV-NNIF1 XNX transmitter, HART over 4-20mA output,
ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, including MPD IR
Hydrocarbon (Propane) sensor 0-100LEL
XNX-AMAV-NHIF1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional local HART interface port, including MPD IR Hydrocarbon (Propane)
sensor 0-100LEL
XNX-AMAV-RNIF1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional alarm and fault relay outputs, including MPD IR Hydrocarbon (Propane)
sensor 0-100LEL
XNX-AMAV-RHIF1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional alarm and fault relay outputs and local HART interface port, including
MPD IR Hydrocarbon (Propane) sensor 0-100LEL
XNX-AMAV-MNIF1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional ModBus output, including MPD IR Hydrocarbon (Propane) sensor 0-100LEL
XNX-AMAV-MHIF1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional ModBus output and local HART interface port, including MPD IR
Hydrocarbon (Propane) sensor 0-100LEL
XNX-AMAV-FNIF1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional Foundation Fieldbus output, including MPD IR flammable sensor
0-100LEL.
XNX-AMAV-FHIF1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional Foundation Fieldbus output and local HART interface port, including
MPD IR flammable sensor 0-100LEL.
Honeywell Analytics XNX Universal Transmitter XNX-AMAV-NNIF1
XNX Stainless Steel Transmitter ATEX/IEC with MPD
Infrared Methane Sensor 0-100LEL (0-5%V/V)
XNX-AMSV-NNIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel,
including MPD IR methane sensor 0-100LEL (0-5%V/V)
XNX-AMSV-NHIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with
optional local HART interface port, including MPD IR methane sensor 0-100LEL
(0-5%V/V).
XNX-AMSV-RNIV1 XNX transmitter, HART over 4-20mA output,
ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional
alarm and fault relay outputs, including MPD IR methane sensor 0-100LEL
(0-5%V/V)
XNX-AMSV-RHIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with
optional alarm and fault relay outputs and local HART interface port, including
MPD IR methane sensor 0-100LEL (0-5%V/V)
XNX-AMSV-MNIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with
optional ModBus output, including MPD IR methane sensor 0-100LEL (0-5%V/V)
XNX-AMSV-MHIV1 XNX transmitter, HART over 4-20mA output,
ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional
ModBus output and local HART interface port, including MPD IR methane sensor
0-100LEL (0-5%V/V)
XNX-AMSV-FNIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with
optional Foundation Fieldbus output, including MPD IR methane sensor 0-5%V/V
Honeywell Analytics XNX Universal Transmitter XNX-AMAV-NNIF1
XNX-AMSV-FHIV1 XNX
transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries,
painted 316 stainless steel, with optional Foundation Fieldbus output and local
HART interface port, including MPD IR methane sensor 0-5%V/V.
XNX Aluminium
Transmitter ATEX/IEC with MPD Infrared Methane Sensor 0-100LEL (0-5%V/V)
XNX-AMAV-NNIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, including
MPD IR methane sensor 0-100LEL (0-5%V/V)
XNX-AMAV-NHIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional local HART interface port, including MPD IR methane sensor 0-100LEL
(0-5%V/V)
XNX-AMAV-RNIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional
alarm and fault relay outputs, including MPD IR methane sensor 0-100LEL
(0-5%V/V)
XNX-AMAV-RHIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional alarm and fault relay outputs and local HART interface port, including
MPD IR methane sensor 0-100LEL (0-5%V/V)
XNX-AMAV-MNIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional ModBus output, including MPD IR methane sensor 0-100LEL (0-5%V/V)
XNX-AMAV-MHIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional ModBus output and local HART interface port, including MPD IR methane
sensor 0-100LEL (0-5%V/V)
XNX-AMAV-FNIV1 XNX transmitter, HART over 4-20mA
output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with
optional Foundation Fieldbus output, including MPD IR methane sensor 0-5%V/V
Honeywell Analytics XNX Universal Transmitter XNX-AMAV-NNIF1
XNX-AMAV-FHIV1 XNX
transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries,
painted LM25 aluminium, with optional Foundation Fieldbus output and local HART
interface port, including MPD IR methane sensor 0-5%V/V
Honeywell Analytics XNX Universal Transmitter XNX-AMAV-NNIF1