Horizontal-vertical flame chamber tester,the products which were tested in both vertical and horizontal orientation has the function automatically follow flame in the cross of the test.
Horizontal-vertical flame chamber tester
1.Overview:
When there is a fire around the products, should ensure that it will not to cause the spread of the fire, horizontal-vertical burning test simulates electronic products around the environment in the early condition, using the simulation technology to assess the fire risk. The test equipment apply to the electrical and electronic product components of household appliances, spare parts and components, such as: household appliances insulation shell, Panel switches, printed circuit boards and insulation materials and so on.
2.Characteristics
Horizontal-vertical flame chamber tester is composed by the test part and control part, using the integrated design, to facilitate the installation at the scene and debug. The shell of the test chamber and the important parts are all manufactured by stainless steel, resistant cigarettes and gas corrosion. The automatic degree of control system is high. Has automatic ignition, the products which were tested in both vertical and horizontal orientation has the function automatically follow flame in the cross of the test. Time and temperature figures show, so that the observation and records is facilitate and the use of it is stable and reliable.
Power
supply: AC220V±10%/50Hz。(Other power specifications can
be customized).
Model
|
According to the standard
|
Average volume
|
Appearance size
|
Weight
|
Technical requirement
|
Configuration
|
|
SH5301/
|
The Old GB of GB11020-89/the old standard of UL94
|
0.15
|
710 (width) x365 (depth) x760 (height)
/1000 (width) x 600 (depth) x 1260 (height)
|
30/
50
|
Use the gas or liquefied petroleum gas as the source gas of the pilot flame (Under the conditions of the proposed, suggest the elect of temperament better gas )The diameter of the burner is ¢ 9.5 ± 0.5mm, 100mm long, has the air-conditioned hole. The height of the flame is moderate, according to standards can be transferred from 20mm to 175mm. The imposing time and holding time of the flame can be adjusted in the scope of 0 to 99 minutes and 99 seconds. The process of the test is automatic control.
|
Without flowmeter and pressure regulator (automatic ignition)
|
SH5301A
|
0.75
|
SH5302/
|
GB5169.7.14.15. 16-2002and the relevant standard of IEC
|
0.15
|
710 (width) x365 (depth) x760 (height)
/1000 (width) x600 (depth) x 1260 (height)
|
40/
65
|
Use the gas or liquefied petroleum gas as the source gas of the pilot flame (Under the conditions of the proposed, suggest the elect of temperament better gas ).The type of burner is the pre-mixed one, and the diameter is ¢12±0.5mm, 100mm long. The height of the flame is moderate, according to standards can be transferred from 20mm to 175mm. The imposing time and holding time of the flame can be adjusted in the scope of 0~99 minutes and 99 seconds. The process of the test is automatic control.
|
With double- Flowmeter and Pressure Regulator
|
SH5302
A/B/C
|
0.5/0.75/1
|
SH5302/T
|
GB5169.7-2002and the relevant standard of IEC
|
0.15
|
With double-flowmeter and Pressure regulator, with temperature and time measurement device
|
SH5302
A/B/C/T
|
0.5/0.75/1
|
SH5304
|
UL94-2003
|
0.5
|
1000 (width) x600 (depth)x1260 (height)
|
>65
|
Use the gas or liquefied petroleum gas as the source gas of the pilot flame (Under the conditions of the proposed, suggest the elect of temperament better gas )The diameter of the burner is ¢ 9.5 ± 0.5mm, 100mm long, has the air-conditioned hole. The height of the flame is moderate, according to standards can be transferred from 20mm to 175mm. The imposing time and holding time of the flame can be adjusted in the scope of 0 to 99 minutes and 99 seconds. The process of the test is automatic control.
|
With flowmeter and pressure regulator (automatic ignition)
|