Environmental Chambers ; Environmental Chambers China
Temp. & Humid. Chambers
Temp. & Humid. Chamber (TG / ICH type)
Temp. & Humid. Chambers (Table-top)
Temperature Chambers (Table-top)
Clean Temperature & Humidity Chambers
Plant Growth Chambers
General Application
| Description | Operating Temp. Range (℃/℉) | Operating Humid. Full Range 2) (%RH) |
Temp.& Humid. Chambers (Floor Standing Models) | TH-G Models | -35 to 150 / -31 to 302 | 25 to 98 |
| TH-I Models | 25 to 98 |
| TH-GU-300 | -60 to 150 / -76 to 302 | 25 to 98 |
| TH-TG Models | -5 to 100 / 23 to 212 | 10 to 95 |
| TH-ICH 3) Models | -5 to 85 / 23 to 185 | 20 to 85 |
Temp. & Humid. Chambers (Tabletop Models) | TH-KE Models | -35 to 150 / -31 to 302 | 20 to 95 |
| TH-ME Models | -20 to 150 / -4 to 302 | 20 to 95 |
| TH-PE Models | 0 to 120 / 32 to 248 | 30 to 95 |
| Clean Temp. & Humid. Chamber | TH-CR-270 | -35 to 100 / -31 to 212 | 30 to 90 |
1) Operating temperature ranges obtained without using humidity.
2) Please, refer to the specification details in the catalog. Hongzhan Temperature Chambers
Test for reliability, durability, climatic, freezing resistance, quality assurance, thermal endurance etc.
- Testing for electric and electronic component, sensors.
- Testing for semiconductor, PCB, LCD & LED.
- Pharmaceutical tests.
- Mechanical / Military / Aircraft engineering.
- Automobile, Transport / automobile supply industries.
- Chemical / Petrochemical industries.
- Construction materials / Plastic / Textile industries.
- Testing mould, liquor, cigar, paintings.
- Testing metal related industries like plating etc.
Hongzhan Temperature & Humidity Chambers
Test for reliability, durability, climatic, freezing resistance, quality assurance, thermal endurance etc.
- Testing for electric and electronic component, sensors.
- Testing for semiconductor, PCB, LCD & LED.
- Pharmaceutical tests.
- Mechanical / Military / Aircraft engineering.
- Automobile, Transport / automobile supply industries.
- Chemical / Petrochemical industries.
- Construction materials / Plastic / Textile industries.
- Testing mould, liquor, cigar, paintings.
- Testing metal related industries like plating etc.
Plant Growth Chambers
- Agriculture experiment with growth of plants.
- Growth experiment of animals and insects.
- Food preservation experiments.
- Genetic of life science researches.
- Genetic researches and pathology of plants.
- Retardation researches of seeds.
- Tissue culture of plants and germinating researches of seeds.
Technical Benefits
- Temperature Chambers
- Safety Features 1) Self-protecting cut-off function:
- Over temperature, electrical leakage or over voltage automatically cuts the power from the unit, in an orderly fashion, starting with the heating element then the controller unit.
2) Time setting function for automated RUN / OFF: - Enable automatic start and shut off of a unit at any specific time.
- A timer can be set for a month and data can be recorded in time, day, or week intervals.
3) Door-open warning alarm: - Intermittent toned alarm audible alarm and visual alarms.
- Heating element, fan, and platform automatically stops when the door is opened to minimize heat loss and to ensure users safety.
Safety Features 1) Microprocess PID control / Auto-tuning / Calibration.
2) Optimize CPU logic control system. - Optimum control of temperature with economical controls that reduces power consumption.
3) Touch screen type display. - 5.7-inch Color LCD display with interactive input system. ( Floor Standing Models only)
- Temperature / timer settings, and operation condition.
- Temp., other operating parameters can be recorded using a chart recorder.
- Easily visible set value: set point (SP) / pre-sent value (PV) are also added on the colorful LCD controller.
Protect the Global Environment 1) Use of HFC refrigerant prevents damage to the ozone layer.
2) Complies with the Montreal Protocol on Substances That Deplete the Ozone Layer control measures.
- Temperature & Humidity Chambers
- Safety Features 1) Self-protecting cut-off function:
- Over temperature, electrical leakage or over voltage automatically cuts the power from the unit, in an orderly fashion, starting with the heating element then the controller unit.
2) Time setting function for automated RUN / OFF - Enable automatic start and shut off of a unit at any specific time.
- A timer can be set for a month and data can be recorded in time, day, or week intervals.
3) Low fluid level protection water leakage alarm - Intermittent toned alarm audible alarm and visual alarms.
- Water supply and circuit compartment separate from each other to ensure safety.
4) Door-open warning alarm - Intermittent toned alarm audible alarm and visual alarms.
- Heating element, fan, and platform auto-matically stops when the door is opened to minimize heat loss and to ensure users safety.
Optimum control Features 1) Microprocess PID control / Auto-tuning / Calibration.
2) Optimize CPU logic control system. - Optimum control of temperature / humidity with economical controls that reduces power consumption.
3) Touch screen type display. - 7-inch Color LCD display with interactive input system. (Floor Standing Models only)
- Temperature & humidity timer settings, and operation condition.
- Temperature & humidity and other operating parameters can be recorded using a chart recorder.
- Easily visible set value: set point (SP) / present value (PV) are also added on the colorful LCD controller.
Protect the global environment 1) Use of HFC refrigerant prevents damage to the ozone layer.
2) Complies with the Montreal Protocol on Sub-stances That Deplete the Ozone Layer control measures.