BSC-1000IIA2 BSC-1300IIA2 BSC-1600IIA2
Clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as medicine, pharmacy, scientific research and so on.
Main characters
1 It accords with physical engineering principle, 10°inclination design, so the operating feel is more excellent.
2 Air insulation design to avoid cross pollution inside and outside air circulation . 70% Air Recirculation, 30% Air Exhaust,vertical laminar negative pressure.
3 Equipped with spring up/down movable door in the front and back of work bench, flexible and convenient to locate
4 Equipped with special filter on ventilation to keep vented air conforming to national standard.
5 Contact switch adjusts voltage to keep wind speed in working area in ideal state all the time.
6 Operate with LED panel.
7 The material of the work area is 304 stainless steel.
|
Parameter / model
|
BSC-1000IIA2
|
BSC-1300IIA2
|
BSC-1600IIA2
|
|
Cleaning level
|
100 Level(USA Federal Standard 209E)≥0.5um Granulae≤3.5per liter
|
|
Descending wind speed
|
≥0.35m/s
|
|
Wind speed in
|
≥0.55m/s
|
|
Noise
|
≤58dB(A)
|
|
Half ventilation peak value
|
≤3µm
|
|
Power supply/Max. power consumption
|
AC220V/50HZ/1KW
|
|
Biological safety
|
Personnel protection: impact type sampler: CFU≤10,
|
|
Product protection: all sampling vessels: CFU≤5
|
|
Cross contamination protection: all double dishes: CFU≤2
|
|
working area
|
1000*650*580
|
1300*650*580
|
1600*650*580
|
|
Overall dimension
|
1200*750*1950
|
1500*750*1950
|
1800*750*1950
|
|
Specification of air-supply filter
|
955*545*50*1
|
1290*554*50*1
|
1590*554*50*1
|
|
Specification and number of fluorescent lamp or UV lamp
|
20W*2/20W*1
|
30W*2/30W*1
|
30W*2/30W*2
|
|
Illumination
|
≥650LX
|
≥650LX
|
≥650LX
|
|
Weight(kg)
|
300
|
340
|
380
|
|
Suit
|
Single
|
Double
|
Double
|
BSC-1000IIB2 BSC-1300IIB2 BSC-1600IIB2
Clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as medicine, pharmacy, scientific research and so on.
Main characters
1 It accords with physical engineering principle, 10°inclination design, so the operating feel is more excellent.
2 Air insulation design to avoid cross pollution inside and outside air circulation within100% exhaust, vertical laminar negative pressure.
3 Equipped with spring up/down movable door in the front and back of work bench, flexible and convenient to locate
4 Equipped with special filter on ventilation to keep vented air conforming to national standard.
5 Contact switch adjusts voltage to keep wind speed in working area in ideal state all the time.
6 Operate with LED panel.
7 The material of the work area is 304 stainless steel.
|
Parameter / model
|
BSC-1000IIB2
|
BSC-1300IIB2
|
BSC-1600IIB2
|
|
Cleaning level
|
100 Level(USA Federal Standard 209E)≥0.5um Granulae≤3.5per liter
|
|
Descending wind speed
|
≥0.35m/s
|
|
Wind speed in
|
≥0.55m/s
|
|
Noise
|
≤58dB(A)
|
|
Half ventilation peak value
|
≤3µm
|
|
Power supply/Max. power consumption
|
AC220V/50HZ/1KW
|
|
Biological safety
|
Personnel protection: impact type sampler: CFU≤10; narrow slot type sampler: CFU≤5
|
|
Product protection: all sampling vessels: CFU≤5
|
|
Cross contamination protection: all double dishes: CFU≤2
|
|
working area
|
1000*650*580
|
1300*650*580
|
1600*650*580
|
|
Overall dimension
|
1200*750*1950
|
1500*750*1950
|
1800*750*1950
|
|
Specification of air-supply filter
|
955*545*50*1
|
1290*554*50*1
|
1590*554*50*1
|
|
Specification and number of fluorescent lamp or UV lamp
|
20W*2/20W*1
|
30W*2/30W*1
|
30W*2/30W*2
|
|
Illumination
|
≥650LX
|
≥650LX
|
≥650LX
|
|
Weight(kg)
|
300
|
340
|
380
|
|
Suit
|
Single
|
Double
|
Double
|