Product characteristics
1. Air curtain isolation design, preventing internal and external cross contamination, 30% air flow outward 70% internal circulation, negative pressure vertical laminar flow, no need to install pipelines.
2, up and down mobile glass door, can be arbitrary positioning, easy to operate, and can be completely closed for sterilization, positioning height limit alarm prompt.
3, the work area power output socket, equipped with waterproof socket and sewage interface to provide great convenience for the operator
Special filter is set at the exhaust air to control the emission of pollution.
5, the working environment adopts high quality 304 stainless steel, smooth, seamless, no dead Angle, easy to thoroughly disinfection, can prevent corrosion and disinfectant erosion.
6. LED liquid crystal panel control.
7. Equipped with high-efficiency filter failure alarm function.
8. Outflow alarm of working area.
9.10° inclination Angle, in line with the human body design concept
Technical parameters
|
model
specification
|
BSC-1000IIA2
|
|
Cleanliness
|
Grade 100 @≥0.5 micron (USA 209E)
|
|
Colony count
|
0.5 / dish or less (Φ 90 ㎜ cultivate AGAR)
|
|
Average wind speed
|
inside of the door
|
0.38±0.025m/s
|
|
In the middle
|
0.26±0.025m/s
|
|
In the side
|
0.27±0.025m/s
|
|
Front suction wind speed
|
0.55m±0.025m/s(30% air exhaust)
|
|
noise
|
≤62dB(A)
|
|
Half peak of vibration
|
≤3μm
|
|
Power
|
AC Single phase220V/50Hz
|
|
maximum power consumption
|
1000W
|
|
Weight
|
150㎏
|
|
Working area
|
W1×D1×H1
|
800×550×620
|
|
Overall dimension
|
W×D×H
|
1000×800×2100
|
|
Hepa filter specification and quantity
|
840*470*70;500*400*70
|
|
Specification and quantity of fluorescent/ultraviolet lamps
|
14W×①/14W×①
|