Zhejiang FUXIA Medical Technology Co.,Ltd.
Main camp product:
Laminar flow cabinet
air sampler
pass box and weighing booth
Air shower
Class 100 clean cabinet
Class II biological safety cabinet
Fume hood
Clean sampling vehicle
Home
Intro
Product
News
Article
Download
Job
Contact
Product Search
Contact Us
Contact person:July Mobile phone:+86-18158752208 Zip code:312300 Address:Beside 104 National Road, Daoxu Street, Shangyu District, Shaoxing City, Zhejiang Province Email:zjsjsales002@hotmail.com QQ:3366561937 Wechat:zjsjsales002 Whats app:+86-18158752208 Skype:julyzjsj
Browse by Category
Laminar flow cabinet
Biological safety cabinet
Fume hood
Pass box
air shower
Autoclave/Steam sterilizer
Incubator
Drying Oven
Clean sampling vehicle
Medical hand washing sink
Weighing booth
Particle counter
Air sampler
Muffle furnace
water distiller
ozone generator
water bath
Air purifier
vacuum pump
Colony counter
News
Guidelines for the Use of Microbial Biosafety Cabinets
Biosafety cabinets are essential safety equipment in laboratories, mainly used to protect laboratory personnel, specimens, and the environment from infectious hazards. It forms a negative pressure state inside the cabinet through directional air flow, preventing aerosol leakage and protecting operators. The outside air is efficiently filtered and enters the safety cabinet to prevent sample contamination; The air inside the cabinet is also efficiently filtered and discharged to protect the environment.
Classification and Typing
Biosafety cabinets are divided into level one, level two, and level three, and the appropriate level should be selected according to different needs.
The models are divided into A1, A2, B1, and B2, each with different applicable scenarios.
Usage steps
Turn on the power and start the biosafety cabinet.
Turn on the ultraviolet lamp and irradiate for 30 minutes for disinfection.
After disinfection, turn on the lighting and fan.
Press and hold the glass cabinet door to start the operation.
Work precautions: Do not block the fan, all specimens should be opened in the biosafety cabinet, and do not extend your arms outside the cabinet during operation.
After finishing, wipe the cabinet with alcohol, press and hold the lower glass cabinet door, turn off the inoculation ring electric heater switch and fan, and turn on the ultraviolet lamp again for irradiation.
By following the above steps, the safety of the laboratory can be effectively ensured, avoiding cross contamination and personnel injury.